Glass Vial,Glass Bottle,Glass Tube Glass Ampoule,Caps Or Seals,Moulded Vials Co., Ltd. , http://www.ns-pharmaceutical.com
Â
Â
Embedded handle allows for easy transportation
Intuitive programming procedure with quick guidance on screen
Safety
High accuracy: ±2%, satisfying neonatal use
Fast start function and Anti-bolus function, ensure patients' safety
IP34 dust and water protection
Connectivity
Nurse call/ RS 232/ DC input
Â
Specifications and functions
Â
Dimension
381 x 228 x 160mm
Syringe size
5, 10, 20, 30, 50/60ml
Â
Â
Â
Infusion mode
Rate mode, Time mode, Body weight mode, Intermittent administration mode
Flow rate range
5ml syringe: (0.1~150)ml/h; 10ml syringe: (0.1~300)ml/h; 20ml syringe: (0.1~600)ml/h
30ml syringe: (0.1~900)ml/h; 50ml/60ml syringe: (0.1~1500)ml/h
Â
Â
Â
Â
Â
Accumulated volume
0.1~9999 ml
VTBI
0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml
Increment
0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h
Accuracy
≤ ±2%
KVO rate
0.1-5.0 ml/h, adjustable, increment is 0.1ml/h
Â
Â
Â
Bolus rate
0.10-1500ml/h
Purge rate
150-800ml/h
Occlusion
Low 150±125 mmHg (20kPa); Medium 300±125 mmHg (40kPa);
Medium high 525±125 mmHg (70kPa); High 900±180 mmHg (120 kPa)
Â
Â
Â
Â
Â
Screen
3.0'' LCD monochrome screen, 240 x 128 pixels
Â
Â
Â
Titration
Yes, increment is 0.1ml/h
Â
Â
Â
Keypad lock
Yes
Pause
Yes
Automatic recognition of syringe size
Yes
Â
Â
Â
Self-test system
Yes
Â
Â
Â
Last therapy parameter memory
Yes
Â
Â
Drug library
200 drugs
Â
Â
Â
History record
1500 events
Weight
<3.6kg (not including clamp)
Handle
Embedded handle
Mounting type
Standard: Vertical Pole
Alarm Volume
1-8 Â levels selectable
Â
Â
Â
Preset syringe brand
Include B-D Luer-Lok Tip,B.Braun OPS,Terumo SS; Local brand configuration supported
Â
Â
Â
Language
2, Chinese, English
Â
Â
Â
Alarm
Â
Â
Â
VTBI done, VTBI near done, KVO finish, syringe empty, syringe near empty,
Â
Â
syringe not installed, syringe disengaged, occlusion, system error, system
Â
Â
abnormal, battery low, battery empty, reminder, AC power disconnection,
Â
Â
standby time expired
Â
Â
Â
Safety Requirement
Â
AC power
100-240V (50/60Hz, 0.8-0.28A)
DC power
10-16V (4.0-2.5A)
Battery type
Lithium
Â
Â
Â
Battery operation time
Standard: ≥5 hours@5ml/h for single channel, ≥3 hours@5ml/h for double channel;
Optional: ≥10 hours@5ml/h for single channel, ≥6 hours@5ml/h for double channel
Â
Â
Â
Â
Â
Charging time
Standard: ≤6 hours; Optional: ≤12hours
Â
Â
Â
Classification
CF, Class I
Â
Â
Â
IP Grade
IP 34
Temperature
5~40ºC for operating, -20~60ºC for storage
Â
Â
Â
Humidity
15~95% Â for operating, 10~95% for storage
Â
Â
Â
Air pressure
Â
57~106kPa for operating, 50~106kPa for storage
Â
Â
Â
Â
Interface
Â
Â
Data interface
Â
Supported, RS232
Â
Â
Â
Nurse Call
Â
Supported
DC input
Â
Supported
Â
Â
Â
Automatic relay function
Â
Supported
Â
Â
Â
Â
Â
Medical Electric Syringe Pump 2 Channel with Rate Time Body Weight Mode>
Model NO.: 500III
Needle: Without Needle
Syringe Use: High Precision Experiments, Samples, Mixing Potions, Pumping Water, Intramuscular Injection
Disinfection: Without Disinfection
Medical Device Regulatory Type: Type 2
Infusion Mode: Rate Mode, Time Mode, Body Weight Mode, Intermitte
Syringe Size: 5, 10, 20, 30, 50/60ml
Accuracy: 2%
Flow Rate Range: 0.1-1500ml/H
Vtbi: 0.1~999.9 Ml
Kvo Rate: 0.5ml/H
Color: White
Screen: 3.0′′ LCD Monochrome Screen
Weight: Less Than 3.6kg Not Including Clamp
Battery Operation Time: More Than 6 Hours
Trademark: Perlong
Transport Package: Standard
Specification: CE / ISO
Origin: Jiangsu, China
HS Code: 9018390000
500III New Syringe PumpÂ
Â
Friendliness
Â
User friendly keypad design
Next Article
The Different Color Hand Warm PVC Hot Water Bag
Prev Article
(2016) High-Brightness Economic Examination Light